this post was submitted on 29 Nov 2023
0 points (50.0% liked)
Home Networking
198 readers
1 users here now
A community to help people learn, install, set up or troubleshoot their home network equipment and solutions.
Rules
- Please stay on topic.
- Please use the search function to look for keywords related to what you want to ask before posting since most common issues have been answered.
- No Ads. This community is for support and discussion. Ads and self promotion are not welcome here.
- No product reviews or announcements. If you have a question about a product, be specific about what you want to know.
- Be civil. Don't be a jerk. Not being a jerk is surprisingly easy.
- No URL shorteners. URL shorteners tend to hide the real use of a link. For this reason, please use normal links, even if they're long.
- No affiliate links.
- No gatekeeping. With profession shall come professionalism. Extend help without judging others for their ignorance. The same goes for downvoting of comments or posts for "stupid questions" or not being as knowledgeable as others.
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
Most electricians still do not know how to terminate in 2023--and this is after seeing what type of garbage work they did in 1995 at my parent's home--NOTHING has changed in nearly 30 years. I would have them run the wiring and do my own termination. Use the money saved on termination to double up on wires in case one is damaged when being run.
That is pretty surprising isn't it? I do feel it's more complex than power wires, but not by much. And to be fair I've rewired a few ceiling fan/lights in my day or 2-switch light controls and the wording on those instructions makes ZERO sense. "be sure to attach the hot wire to the hot terminal on the fixture" ... but the fixture has zero indicators to which side is hot/cold and is symmetric to the drawing. However, one plate is copper and the other is silver (in color), so there IS a difference but what is it? stupid engineers. Don't say "hot/cold" or "+/-" for a device that can only be identified as "silver/copper". :p
It's just more precise work to do it right. Idiot working upstairs at my parent's house untwisted 3" before terminating jacks. And that's why those jacks only get 100Mbs. I'm going to have to re-terminate all of them, and have been saying that for nearly 30 years now! Thank God they didn't terminate all the jacks so I've got a shot at doing those right. The ones that were terminated correctly will iperf 700-900Mbs, so that's pretty good considering there was no gigabit standard when the wire was installed and was the only 400Mhz rated wire on the market that cost us 2x as much, but was a great investment. If 2.5Gb/5Gb runs over it, that will be pretty awesome. We put 2x ethernet and 2x coax in each room and still have areas that were underserved. 2x of each on each wall and ceiling is the only way to go.